Home · Test Protocols

Testing that goes beyond the benchmark.

116 to 152 barBurst · 1st carcass
GMPHOM 2009GMPHOM standard
5 testsPer hose
100% of batchesFinal acceptance

Burst from 116 to 152 bar, above the GMPHOM 2009 minimum. No hose leaves the factory without the full battery: burst on the first and second carcass, nipple adhesion, hydrostatic proof and final acceptance testing on 100% of batches. The figures below are what engineering measures, and they sit above what the norm requires.

Burst Test · first carcass
Performance above the GMPHOM 2009 minimum.
Burst on the first carcass is the test that sets the safety margin of the hose. The four configurations below compare 12″ and 24″ bores, in single and double carcass, against the minimum the norm requires.
GMPHOM · minimum
SC 12″DC 12″SC 24″DC 24″
Single carcass Double carcass
First-carcass burst (SC/DC · 12″/24″) above the GMPHOM 2009 minimum. Illustration: exact figures available on technical request.
Test protocols
Factory Acceptance Tests · a battery of tests per hose.
Official factory acceptance test (FAT) list, per GMPHOM 2009 and the client specification. The last four apply depending on the project.
Adhesion
Buoyancy / Weight
Minimum Bend Radius
Hydrostatic
Temporary Elongation
Permanent Elongation
Hose Length
Vacuum
Tensile loadif required
Torsion loadif required
Stiffnessif required
Keroseneif required
Vendor Data Bookdocumentation
Certifications & qualification
Qualified to international standards.
Full qualification to international standards and prototype certificates by bore (14″–24″ · 21 bar, floating and submarine).
GMPHOM / GMPHOM 2009industry reference standard
ISO 9001quality management system
24″ Double Carcassqualified prototype
24″ Single Carcassqualified prototype
12″ Double Carcassqualified prototype
12″ Single Carcassqualified prototype
Want the test dossier for your model? Engineering sends the technical report for the bore you operate, on request.
Talk to engineering →